OIL AND GAS

The Arkansas Oil and Gas Commission last week issued 8 well recompletions. There were no drilling permits or well completions issued. By county, they were:

WELL RECOMPLETIONS

CLEBURNE -- BHP Billiton Petroleum (Fay) of Houston for Bennett Trust No. 9-12 2-11H14, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 11,074 ft., perf. 4,099-10,954 OA ft. Loc. SHL: 404 ft. FNL & 1,110 ft. FEL and BHL: 2,559 ft. FNL & 1,156 ft. FEL of Sec. 11-9N-12W. Workover done June 16.

Seeco LLC. of Spring for Austin No. 11-09 1-33H28, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 7,974 ft., perf. 2,890-7,868 OA ft. Loc. SHL: 532 ft. FNL & 989 ft. FEL and BHL: 469 ft. FNL & 1,841 ft. FEL of Sec. 33-11N-9W. Workover done June 13.

XTO Energy Inc. of Oklahoma City for Lacy No. 2-34H, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 7,461 ft., perf. 2,827-7,352 OA ft. Loc. SHL: 334 ft. FSL & 1,496 ft. FWL and BHL: 10 ft. FNL & 1,057 ft. FWL of Sec. 34-11N-9W. Workover done June 8.

CONWAY -- XTO Energy Inc. for Frederick No. 2-32H, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 10,649 ft., perf. 6,115-10,522 OA ft. Loc. SHL: 240 ft. FSL & 1,668 ft. FEL and BHL: 186 ft. FNL & 1,709 ft. FEL of Sec. 32-8N-16W. Workover done June 19.

FAULKNER -- Seeco LLC. for Linda Linn No. 08-12 9-23H11, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 12,304 ft., perf. 6,774-12,236 OA ft. Loc. SHL: 407 ft. FNL & 994 ft. FWL and BHL: 944 ft. FSL & 122 ft. FWL of Sec. 23-8N-12W. Workover done June 19.

INDEPENDENCE -- XTO Energy Inc. for Otis No. 1-25H, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 7,008 ft., perf. 2,655-6,882 OA ft. Loc. SHL: 200 ft. FSL & 1,555 ft. FWL and BHL: 454 ft. FNL & 593 ft. FWL of Sec. 25-11N-6W. Workover done June 25.

WHITE -- BHP Billiton Petroleum (Fay) for Harris No. 8-9 2-26H, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 9,884 ft., perf. 5,859-9,781 OA ft. Loc. SHL: 200 ft. FSL & 1,045 ft. FWL and BHL: 490 ft. FNL & 1,161 ft. FWL of Sec. 26-8N-9W. Workover done June 16.

XTO Energy Inc. for Tanner No. 3-31H, 24-hr. prod. not available in Fayetteville Form. of B-43 Fld. Drilled to TD: 10,770 ft., perf. 6,020-10,652 OA ft. Loc. SHL: 183 ft. FSL & 479 ft. FEL and BHL: 16 ft. FNL & 167 ft. FEL of Sec. 31-8N-8W. Workover done June 23.

ABBREVIATIONS

Loc. -- location; Perf. -- perforations; FEL -- from the east line; FNL -- from the north line; FSL -- from the south line; FWL -- from the west line; FEUL -- from the east unit line; FWUL -- from the west unit line; FNUL -- from the north unit line; FSUL -- from the south unit line; MCF -- thousand cubic feet; bbl -- barrel; MD -- measured depth; TD -- total depth; TVD -- true vertical depth; PBTD -- plug back total depth; BHL -- bottom hole location; PBHL -- proposed bottom hole location; SHL -- surface hole location; OA -- overall; N/A -- not available.

SundayMonday Business on 07/22/2018

Upcoming Events